1,699 research outputs found

    Hexagonal ABCABC as semiconducting ferroelectrics

    Full text link
    We use a first-principles rational-design approach to identify a previously-unrecognized class of ferroelectric materials in the P63mcP63mc LiGaGe structure type. We calculate structural parameters, polarization and ferroelectric well depths both for reported and as-yet hypothetical representatives of this class. Our results provide guidance for the experimental realization and further investigation of high-performance materials suitable for practical applications.Comment: 5 pages, 2 figures, 3 table

    The future of connectivity conservation

    Full text link

    Load Sharing in Gravel Decked Log Stringer Bridges

    Get PDF
    Log bridges are an economical alternative to steel and concrete structures for temporary crossings; however, reduced availability of large logs for stringers and the advancing age of existing log bridges increases the importance of structural analysis. Load sharing between the stringers is complicated and can result from load spread due to the gravel deck, cable lashing, and mechanical interlocking and friction between the stringers. This paper describes the development of a finite element model (FEM) for gravel decked log stringer bridges that includes elements capable of transferring vertical loads between the stringers. The FEM was used to interpret load deflection data from two in-situ bridges. The results of this paper suggest the segments of lashing that pass under one stringer and over an adjacent stringer contribute to load sharing between the stringers; however, care must be taken to ensure that the pattern of lashing supports the stringers directly loaded by the live loads

    Entangled Rings

    Get PDF
    Consider a ring of N qubits in a translationally invariant quantum state. We ask to what extent each pair of nearest neighbors can be entangled. Under certain assumptions about the form of the state, we find a formula for the maximum possible nearest-neighbor entanglement. We then compare this maximum with the entanglement achieved by the ground state of an antiferromagnetic ring consisting of an even number of spin-1/2 particles. We find that, though the antiferromagnetic ground state does not maximize the nearest-neighbor entanglement relative to all other states, it does so relative to other states having zero z-component of spin.Comment: 19 pages, no figures; v2 includes new results; v3 corrects a numerical error for the case N=

    Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan

    Get PDF
    ObjectiveEarly in our experience with endovascular aortic aneurysm repair (EVAR) we performed both serial computed tomography scans and duplex ultrasound (DU) imaging in our post-EVAR surveillance regimen. Later we conducted a prospective study with DU imaging as the sole surveillance study and determined cost savings and outcome using this strategy.MethodsFrom September 21, 1998, to May 30, 2008, 250 patients underwent EVAR at our hospital. Before July 1, 2004, EVAR patients underwent CT and DU imaging performed every 6 months during the first year and then annually if no problems were identified (group 1). We compared aneurysm sac size, presence of endoleak, and graft patency between the two scanning modalities. After July 1, 2004, patients underwent surveillance using DU imaging as the sole surveillance study unless a problem was detected (group 2). CT and DU imaging charges for each regimen were compared using our 2008 health system pricing and Medicare reimbursements. All DU examinations were performed in our accredited noninvasive vascular laboratory by experienced technologists. Statistical analysis was performed using Pearson correlation coefficient.ResultsDU and CT scans were equivalent in determining aneurysm sac diameter after EVAR (P < .001). DU and CT were each as likely to falsely suggest an endoleak when none existed and were as likely to miss an endoleak. Using DU imaging alone would have reduced cost of EVAR surveillance by 29% (534,356)ingroup1.Costsavingsof534,356) in group 1. Cost savings of 1595 per patient per year were realized in group 2 by eliminating CT scan surveillance. None of the group 2 patients sustained an adverse event such as rupture, graft migration, or limb occlusion as a result of having DU imaging performed as the sole follow-up modality.ConclusionSurveillance of EVAR patients can be performed accurately, safely, and cost-effectively with DU as the sole imaging study
    • …
    corecore